Energy Meter Test Calibration Bench

Energy Meter Test Calibration Bench
Product Detailed
Energy Meter Test Calibration Bench 1. Test bench 2. calibration for Single Phase Energy Meter(Electricity Meter)

Energy Meter Test Calibration Bench

The bench accords with the standard of " IEC 60736: 1982 testing equipment for electrical energy meters" "IEC 62053"The bench can be used to test single phase energy meter (up to 0. 5 class)The bench can do warm up test, starting test, no load test (creep test), error test (accuracy test), dial test, tests of the influence quantities and test of repeatability of the measurements. The bench is using the PWM, technology to amplify voltage/current output, the high efficiency at >85%, and lower the heat. The PWM can check the malfunction checking, preset, alarm, and protection. The signal source is using the newest digital controlled sine wave technology for frequency, amplitude and phase adjust. The bench is using comparison technology to test the error of energy meters. The bench is using the error processor system to calculate the error of each energy meter by the sub-error system, which can be connected by the internal RS485. Different constant energy meter can be tested at one time. Voltage is isolated by MSVT (multi secondary voltage transformer) output, which suits for the voltage/current close-link test of signal phase energy meter The test bench can be installed scanning head; It can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter. The test bench has the auto-search black marker function which can precisely locate the black marker during the no load test and starting test. The bench can choose to operate by keyboard or PC, which is very convenient. The working status of bench can be seen very clear and easy operation. The bench is using the testing software complied with WINDOWS98/2000/XP which can auto-testing different energy meters. The software can realize the data from energy meter for statistics, search and management. The energy meter hanging rack is made by Aluminum compound. The whole device configuration is a reasonable design and nice outfit

SPECIFICATION: The test bench accuracy class: 0. 1/0. 2 classReference standard energy meter:  HY 5101C-22 single phase reference standard energy meterAccuracy class: 0. 05 /0. 1Standard CT (current transformer) class: 0. 01/0. 02MSVT (multi secondary voltage transformer) class: 0. 02Primary voltage: 180-300V (Normal Voltage: 240V)Secondary voltage: 180-300VSecondary VA rating: 15VA per windingInsulation secondary to secondary: 500V, 50Hz, and 60 secondsPrimary to secondary ratio accuracy: +-0. 1% (typical)Secondary to secondary ratio accuracy less than: +-0. 02% Secondary to secondary phase angle accuracy less than +-1 minute Number of secondary output: 8~60channelVoltage amplifier: Output voltage range: 50-288V; Output maximum power: 800VAResolution: 0. 01%; Stability: Better than 0. 05%/3 min (time base 5S); Distortion factor: < 0. 5% at linear load; Frequency range: 45Hz~65Hz; Power efficiency: More than 85%; Ambient temperature: 10C~50CElectronic overload and short-circuit protection. Current amplifier: Output current: Range: 1mA~120A (option for 1mA~200A); Output maximum power: 1500VAResolution: 0. 01%; Stability: Better than 0. 05%/3 min(time base 5S); Distortion factor: < 0. 5% at linear load; Frequency range: 45Hz~65Hz; Power efficiency: Greater than 85%; Ambient temperature: 10C~50CElectronic overload protection and security for open current circuit. Phase Angle: 0~360 degree, resolution of phase angle setting: 0. 1 degree; Output frequency range: 45Hz~65Hz; Resolution: 0. 01HzOutput stability of power: <0. 05% (180S)Numbers of calibrated energy meter: 24 (6/12/24/32/40/48 on requested)Input power: 220/240V 15%, 50/60Hz; Power consumption: Max. 2500VAFEATUR

Energy Meter Test Calibration Bench